What you’re looking at
The heading is Worklist and the subtitle states the job: “The bench queue, oldest first. Filter, select a batch, and mark received oral-fluid screens negative in one pass — urine and non-negatives go through the per-specimen forms.” Along the top, the status chips double as filters and each carries a live count in brackets — All, Lab intake, Collected, In transit, Received, Screening, Confirmed. Beside them are a search box (Specimen ID, LAN or donor…), a specimen-type select offering All specimen types, Oral fluid and Urine, the List | Rack view toggle, and a refresh button with no label on it. The list columns are Specimen, LAN, Donor, Type, Panel (shown as {n} analytes), Status, Received and Where, with a tick box on each row. Next to the status chips is a red Overdue ({n}) chip, and beside the refresh button a Turnaround targets button. The empty state. When nothing matches you get Nothing in the queue for these filters. — widen the filters before you assume something is lost. A lab that runs no regulated collections sees that message on every filter, permanently.See what is overdue
Every sample has a clock that starts when your lab receives it. A sample is Overdue once that clock passes the turnaround target for its specimen type. Select Overdue ({n}) to show only those samples; select it again to go back. Each overdue sample carries a red Overdue badge saying how far past the limit it is. A sample that has not reached your lab yet has no running clock, so it is never overdue; its Where column says where it is. The Where column shows the sample’s last known position, such as In the lab, In transit to the lab or In transit to another lab (a hand-off between your labs outranks everything else), with how long it has been at the lab against its limit. Open a specimen and the same line sits above its workflow, with the Last step and when it happened. If you have not set a target for that specimen type, the worklist compares against your lab’s own average over the last 90 days, once at least five samples of that type have been finished. The badge then says · no target set so you know the limit is your average, not a promise you made. With neither a target nor enough history there is nothing to compare against, and the sample is simply not marked.Set turnaround targets
Open the targets
Enter the hours
Save
Switch between list and rack
Rack view lays the current filter out FIFO and colours each well by status, so an ageing specimen is visible from across the bench. A columns select appears next to the toggle in this view only, offering 5 / row, 6 / row, 8 / row, 10 / row and 12 / row. The caption is the thing to remember: “FIFO layout of the current filter — positions are a bench aid, not stored assignments. Click a well to select it for a batch action; double-click to open the specimen.” Nothing about a well is saved. Move the physical rack and the screen does not follow.Screen a batch negative
Filter to received oral fluid
Select the specimens
Open the batch action
Name the technician
Record the screens
Why urine is excluded
Batch negative is limited to oral fluid on purpose. Urine needs per-specimen validity testing — temperature, creatinine, pH, adulterants — and there is no honest way to attest to that in bulk, so urine is left out of the batch action by design. Work urine through the per-specimen screen form. See Screening and confirmation.Open a single specimen
Selecting a row opens the order workflow sheet with Workflow and Chain of Custody tabs. The Workflow tab shows whichever form the current status calls for — accession, screen, confirmation — so you never have to know which step is next. See Accession an incoming specimen.Who can do this
Role decides whether Worklist opens. Permission decides what you may do on the specimens in it.- Enforcement is opt-in, per person. Somebody never saved in the permissions sheet is unrestricted, and the sheet warns “Saving starts enforcing” — from then on they can only do what is switched on there.
- A denied action is recorded; an allowed one is not. Where a figure is not yours to see it renders hidden or as a dash, never as a zero.
Check it worked
- The specimens you batched have left the Received filter and the Screening count has moved by the same number.
- Each one’s Chain of Custody tab shows an Initial Immunoassay Screen event naming the technician you entered.
- The counts on the status chips add up to the All count.
Common issues
The Worklist is empty
The Worklist is empty
Nothing is ever marked Overdue
Nothing is ever marked Overdue
Mark batch negative is greyed out, or counts zero eligible
Mark batch negative is greyed out, or counts zero eligible
Batch too large — select at most 100 specimens
Batch too large — select at most 100 specimens
A few specimens failed inside the batch
A few specimens failed inside the batch
A specimen screened non-negative
A specimen screened non-negative
Everything on the bench is disabled
Everything on the bench is disabled
I entered the wrong screening technician
I entered the wrong screening technician
FAQ
Why is my Worklist empty?
Why is my Worklist empty?
Do rack positions match my physical rack?
Do rack positions match my physical rack?
Can I batch urine if I ran validity testing on every one?
Can I batch urine if I ran validity testing on every one?
Does a batch negative finish the specimen?
Does a batch negative finish the specimen?
Can I work offline from this queue?
Can I work offline from this queue?